Spesifikasi:
A. Vertical
Deflection
-
Operating modes: Channel I or CH II
separate, Channel I and II: alternate or chopped (Chopper Frequency approx.
0.5MHz)
-
Sum or Difference from Channel I and ±
Ch. II,
-
XY-Mode: via CH I (X) and CH II (Y).
-
Frequency range: 2x DC to 40MHz (−3dB).
Risetime: <8.75ns. Overshoot: ≤1%.
-
Deflection coefficient: 14 calibrated
positions variable 2.5:1 to min. 50V/div.
-
1mV/div and 2mV/div: ±5% (0 to 10MHz
(-3dB))
-
5mV/div to 20V/div: ±3% (1-2-5sequence).
-
Input impedance: 1MΩ II 18pF. Input
coupling: DC - AC - GD (Ground) Input voltage: max. 400V (DC + peak AC).
B. Triggering
-
Automatic(peak to peak): ≤ 20Hz-100MHz(≤0.5div),
Normal: DC-100MHz, LED for trigger indication.
-
Slope: positive or negative.
-
Sources: CH I or II, line, ext. CH I
alternate CH II (≤ 0.8div.)
-
Coupling: AC (≥10Hz -100MHz), DC
(0-100MHz), HF (50kHz - 100MHz), LF (0 - ≤1.5kHz).
-
Triggering ext.: ≥0.3Vpp from DC to
100MHz
-
Active TV-Sync-Separator (field&
line, pos, neg.)
-
2nd triggering (Del. Trig.): normal with
level control DC to 100 MHz.
C. Horizontal
Deflection
-
Time coefficients: 1-2-5 sequence,
Accuracy ±3%
-
Analog: 22 cal. positions from 0.5s - 50ns/div.
-
Digital: 27 cal. positions from 100s -
0,2µs/div. Variable (analog) 2.5:1 up to 1.25s/div.
-
X-MAG. x10: analog to 10ns/div., dig. to
20ns/div±5%.
-
Delay: 120ms - 200ns, variable,
-
Hold-off time (analog): variable to
approx. 10:1.
-
Bandwidth X-amplifier (analog): 0-3MHz
(−3dB). Input X-amplifier via Channel II, Sensitivity see Channel II.
-
X-Y-phase shift : <3° below 120kHz.
D. Digital
Storage
-
Operating modes: Refresh, Roll, Single,
XY, Envelope, Average (2 to 512 waveforms).
-
Automatic Dot Join function
-
Sample Rate: max. 100MS/s (8 bit)
-
Refresh rate: max. 180/s
-
Record length: 2048 x 8 bit per channel.
-
Reference memory Reference memory
Reference memory Reference memory Reference memory: 2 x 2k x 8bit (EEPROM).
-
Resolution: Y: 25 points/div, X: 200
points/div.
-
Pre-/Posttrigger: 25, 50, 75, 100, -25,
-50, -75%.
E. Operation
/ Control
-
Manual (front panel switches);
-
Auto Set (automatic parameter
selection).
-
Save/Recall of 9 user-defined parameter
settings
-
RS232 interface for remote control via a
PC. Remote control (Option) HZ68.
-
Multifunction- Interface HO79-6(Option):
RS232, IEEE-488, Centronics (Postscript, HPGL, PCL, EPSON).
-
Readout: Display of parameter settings.
-
Cursor measurement of ∆V, ∆t or ∆1/t
(frequency), separate or in tracking mode.
F. Component
Tester
-
Test voltage: approx. 7Vrms (open circuit).
-
Test current: max. 7mArms (short
circuit).
-
Test frequency: approx.50Hz One test
lead is grounded (Safety Earth).
G. General
Information
-
CRT: D14-364GY/123 or
ER151-GH/-,rectangular screen (8x10cm) internal graticule
-
Acceleration voltage: approx 2000V
-
Trace rotation: adjustable on front
panel
-
Calibrator: square-wave generator (tr
<4ns) ≈1kHz/1MHz; Output: 0.2V ±1%.
-
Analog Intensitymodulation, max. +5V
(TTL). Line voltage: 100-240V AC ±10%, 50/60Hz
-
Power consumption: approx. 42 Watt at
50Hz. Min./Max. ambient temperature: 0°C...+40°C
-
Protective system: Safety class I
(IEC1010-1) Weight: approx. 6.0kg, color: techno-brown Cabinet: W 285, H 125, D
380 mm